VPD Calculator

Is your grow room too humid, too dry, or just right? Enter the air temperature, the relative humidity and how much cooler your leaves are than the air, and see the leaf VPD in kPa, the dew point, and whether it suits seedlings, veg or flower.

How warm is a leaf?

A leaf is rarely the same temperature as the air around it. Under LEDs it usually runs 1–3 °C (2–5 °F) cooler, since LEDs give off little infrared heat, so −2 °C is a good start. Under HPS a leaf can be as warm as the air or warmer, so try 0 or a little above. An infrared thermometer pointed at a leaf in the light tells you directly: subtract the air temperature from the leaf's and enter the difference, minus sign included when the leaf is cooler.

Leaf VPD

at the leaf

0.91

kPa

Air VPD

in the room

1.27

kPa

Dew point

water condenses at

16.7

°C

Good for vegetative growth (0.8–1.2 kPa).

What is VPD?

VPD, the vapor pressure deficit, is how much more water the air could hold before it's full, in kilopascals (kPa). The bigger it is, the faster your plants transpire water from their leaves and pull it up from the roots, like a wet towel drying fast on a warm, dry day and slowly on a muggy one. Leaf VPD measures it from the leaf, at the leaf's own temperature, which is what the plant feels. Air VPD leaves the leaf out. The dew point is the temperature where the air's water turns to droplets: keep leaves and walls above it, most of all when the lights go off. A leaf VPD below zero means the leaf is already colder than the dew point, so water condenses on it, like condensation forming on a cold glass on a warm day, and mold finds it easy.

Leaf VPD chart (kPa)

Leaf VPD in kPa by air temperature (rows) and relative humidity (columns), with your leaf offset
°C40%45%50%55%60%65%70%75%80%85%
180.990.890.790.680.580.480.370.270.170.06
191.060.950.840.730.620.510.400.290.180.07
201.131.010.890.780.660.540.430.310.190.08
211.201.080.950.830.710.580.460.330.210.08
221.281.151.020.880.750.620.490.360.220.09
231.361.221.080.940.800.660.520.380.240.10
241.451.301.151.000.850.700.560.410.260.11
251.541.381.231.070.910.750.590.430.280.12
261.641.471.301.140.970.800.630.460.290.13
271.741.561.391.211.030.850.670.490.320.14
281.851.661.471.281.090.900.720.530.340.15
291.961.761.561.361.160.960.760.560.360.16
302.081.871.661.451.231.020.810.600.390.17
312.211.981.761.531.311.090.860.640.410.19
322.342.101.871.631.391.150.910.680.440.20
Too humid below 0.4 kPaSeedlings & clones 0.4–0.8 kPaVeg 0.8–1.2 kPaFlower 1.2–1.6 kPaToo dry above 1.6 kPa
About the chart

Each row is an air temperature and each column a relative humidity. Every cell is the leaf VPD there, with the leaf offset you entered, colored by the stage it suits. Your own reading is outlined. If it sits in the wrong color, move across a row to change the humidity, or up and down a column to change the temperature, toward the zone you want. A minus sign, like −0.05, marks a spot where the leaves are colder than the dew point and get wet. The zones are common guidance for cannabis and a starting point for other fruiting crops, so treat their edges as soft.

How to calculate VPD

Leaf VPD = SVP(leaf) − SVP(air) × RH ÷ 100, with SVP (kPa) = 0.6108 × e^(17.27 × T ÷ (T + 237.3)), T in °C

VPD, the vapor pressure deficit, is the air’s drying pull. Warm air can hold more water than cool air. Relative humidity tells you how full the air is, as a percentage. VPD tells you how much room is left, in kilopascals (kPa). Plants transpire water through tiny pores in their leaves, and the bigger that gap, the faster they pull water and nutrients up from the roots. Think of a wet towel. On a warm, dry day it dries in an hour. On a muggy one it stays damp all afternoon.

Too little VPD and the leaves can hardly transpire. Water and nutrients crawl through the plant, and the damp air invites mold and mildew. Too much and the plant closes its pores to save water, which also shuts out the CO2 it needs, so growth stalls and leaf edges curl or crisp. Growers aim for about 0.4–0.8 kPa for seedlings and clones, 0.8–1.2 kPa in veg, and 1.2–1.6 kPa in flower, where the drier air also keeps bud rot away. These ranges are common guidance for cannabis. Treat them as a starting point for other fruiting crops. Leafy greens and houseplants do best at the lower end.

The calculator works out leaf VPD, because the water evaporates from inside the leaf, at the leaf’s own temperature. Under LEDs leaves usually run 1–3 °C (2–5 °F) cooler than the air, since LEDs send out little infrared heat. Under HPS they can be as warm as the air or warmer. An infrared thermometer pointed at a leaf in the light tells you directly. Air VPD leaves the leaf out, so under LEDs it reads higher than what your plants really feel.

To raise VPD, lower the humidity with a dehumidifier or more fresh air, or warm the room a little. To lower it, add a humidifier or cool the room. Keep an eye on the dew point too. When the lights go off and the room cools toward it, water condenses on leaves and walls. Light and VPD go together. More light makes a plant use more water, so a strong light in flower pairs well with a higher VPD. Look up how much light your plant needs with the PPFD & DLI for Plants finder.

The numbers use the Tetens formula for the air’s capacity for water, which is accurate to a fraction of a percent at grow room temperatures. The chart below the results shows the leaf VPD for every temperature and humidity in a typical grow room, with your leaf offset, so you can see which way to move.