LED Kelvin Mixing Calculator

Running white LEDs of different color temperatures in the same fixture? Pick the whites, set how much of the power each one gets, and see the blended Kelvin your light really shows, along with its spectrum.

Blended color temperature

3810 K

How it's calculated

Calculated from the mixed spectrum, the way a color meter reads the light. A blend looks warmer than the plain average of its labels: 50% 2700K with 50% 6500K reads about 4100 K, not 4600 K.

Blue400–499 nm16%
Green500–599 nm45%
Red600–700 nm36%
Far Red701–750 nm2%
About the photon bars

The bars show where the blend's photons fall. Warm whites put more of their light into red, cool whites into blue, so the color temperature also shifts what your plants get.

About the chart

The generated spectrum comes from measured profiles of widely used horticultural LEDs, taken at a typical drive level rather than full power, so it's a reliable way to compare mixes. A finished fixture should land close. Heat, optics and reflectors may alter it slightly, while LED placement or beam angles can shift the color mix across the canopy.

How the blend is calculated

Blended CCT = McCamy (x, y), with x, y from the mixed spectrum and the CIE 1931 color matching curves

Kelvin doesn’t add up in a straight line. The step from 2700K to 3000K changes how warm a light looks about as much as the step from 5000K to 6500K, so the middle of the scale isn’t where the numbers suggest. Mix equal power of 2700K and 6500K and you get about 4100K, not the 4600K a simple average promises.

That’s why this calculator works from the light itself instead of the labels. It adds up the spectra of the whites you pick, each scaled by its share of the power, then finds the color of that combined light with the standard CIE color matching curves, the same way a color meter does. The result is the correlated color temperature, the Kelvin of the white your blend looks like.

Set each share by how much of the fixture’s power goes to that LED type. A board with 60 diodes at 3000K and 40 at 5000K, all driven the same, is 60% and 40%. The photon bars show what the blend means for your plants. Warmer mixes lean toward red, cooler ones toward blue.

A real fixture can land a little off these numbers, since LEDs are sold in color bins around their label. When you set up PPFD METER for this light, pick the light source closest to your blended Kelvin for the most accurate LUX to PPFD reading.